Standard Svensk standard · SS-EN 13725

Luftkvalitet - Bestämning av luktkoncentration med dynamisk olfaktometri

Status: Upphävd

· Ersätts av: SS-EN 13725:2022 Korrigeras av: SS-EN 13725/AC:2006
Köp denna standard

Standard Svensk standard · SS-EN 13725

Luftkvalitet - Bestämning av luktkoncentration med dynamisk olfaktometri
Prenumerera på standarden - Läs mer Dölj
Pris: 1 615 SEK
standard ikon pdf

PDF

Pris: 1 615 SEK
standard ikon

Papper

Pris: 2 584 SEK
standard ikon pdf + standard ikon

PDF + papper

Fler alternativ Färre alternativ
Omfattning
This European Standard specifies a method for the objective determination of the odour concentration of a gaseous sample using dynamic olfactometry with human assessors and the emission rate of odours emanating from point sources, area sources with outward flow and area sources without outward flow. The primary application is to provide a common basis for evaluation of odour emissions in the member states of the European Union. This European Standard is applicable to the measurement of odour concentration of pure substances, defined mixtures and undefined mixtures of gaseous odorants in air or nitrogen, using dynamic olfactometry with a panel of human assessors being the sensor. The unit of measurement is the European odour unit per cubic metre: ouE/m 3 . The odour concentration is measured by determining the dilution factor required to reach the detection threshold. The odour concentration at the detection threshold is by definition 1 ouE/m 3 . The odour concentration is then expressed in terms of multiples of the detection threshold. The range of measurement is typically from 10 1 ouE/m 3 to 10 7 ouE/m 3 (including pre-dilution). The field of application of this European Standard includes: - the measurement of the mass concentration at the detection threshold of pure odorous substances in g/m 3 ; - the measurement of the odour concentration of mixtures of odorants in ouE/m 3 ; - the measurement of the emission rate of odorous emissions from point sources and surface sources (with and without an outward flow), including pre-dilution during sampling; - the sampling of odorants from emissions of high humidity and temperature (up to 200 °C); - the determination of effectiveness of end-of-pipe devices used to reduce odour emissions. The characterisation of odour emissions requires detailed measurement of the gas velocity, that shall be performed according to the relevant standards included in the normative references.

Ämnesområden

Övrigt (13.040.99)


Köp denna standard

Standard Svensk standard · SS-EN 13725

Luftkvalitet - Bestämning av luktkoncentration med dynamisk olfaktometri
Prenumerera på standarden - Läs mer Dölj
Pris: 1 615 SEK
standard ikon pdf

PDF

Pris: 1 615 SEK
standard ikon

Papper

Pris: 2 584 SEK
standard ikon pdf + standard ikon

PDF + papper

Fler alternativ Färre alternativ

Produktinformation

Språk: Engelska

Framtagen av: Luftkvalitet, SIS/TK 423

Internationell titel: Air quality - Determination of odour concentration by dynamic olfactometry

Artikelnummer: STD-34044

Utgåva: 1

Fastställd: 2003-05-09

Antal sidor: 71

Ersätts av: SS-EN 13725:2022