Chimneys - Accessories - Part 4: Flue dampers - Requirements and test methods
Status:
Valid
Buy this standard
StandardSwedish standard
·
SS-EN 16475-4:2020
Chimneys - Accessories - Part 4: Flue dampers - Requirements and test methods
Subscribe on standards with our subscription service. When you use our service you can be assured the latest editions and easy access.
Read more about SIS Subscriptions
This document specifies the characteristics and test methods for flue dampers that are used as components, carrying flue gas, in order to limit the flow in a chimney or to prevent back flow of soot during cleaning of the chimney or to prevent the backflow of the flue gas e.g. in case of multi-served chimneys.
This document covers only flue dampers incorporated in a housing and installed inside a building.
This document covers only flue dampers with sealings made of elastomeric materials for temperature classes up to T 200 and corrosion class 1 or 2 in accordance with EN 14241-1 or sealing materials for dry applications with a fire reaction class A1 in accordance with EN 13501-1.
This document covers only flue dampers with motor drive, casing and flue damper plate which are interlocked in such a way that they can only be separated by using tools.
This document covers only mechanical flue dampers where any motor is in accordance with EN 60730-2-14 and the cover for electrical components of the flue damper fulfils minimum protection class IP40 according to EN 60529.
This document covers only flue dampers which are designed and installed to ensure that incorrect information about the position of the flue damper flap are absolutely impossible, which are only installed on components that are interlocked to the casing, which are only activated by components that are interlocked to the flue damper flap and where it is ensured that the limit switch opens or the flue damper flap moves to the open position if one of these interlocks fails. This safety target may also be achieved with an equally suitable method (e.g. bracing or welding).
This document covers only flue dampers for biomass boilers ≥ 1 000 kW and industrial applications with limit switches in accordance with EN 61058-1 or EN 50156-1.
This document covers only flue dampers where it is possible to identify the position of the flue damper flap.
This document covers only totally closed, manually driven fl ...