Standard Swedish standard · SS-EN 81-72

Safety rules for the construction and installation of lifts - Particular applications for passenger and goods passenger lifts - Part 72: Firefighters lifts

Status: Withdrawn

· Replaced by: SS-EN 81-72:2015 , SS-EN 81-72:2015
Buy this standard

Standard Swedish standard · SS-EN 81-72

Safety rules for the construction and installation of lifts - Particular applications for passenger and goods passenger lifts - Part 72: Firefighters lifts
Subscribe on standards - Read more Dölj
Price: 1 152 SEK
standard ikon pdf

PDF

Price: 1 152 SEK
standard ikon

Paper

Show more Show less
Scope
1.1 This standard applies to firefighters lifts as defined in clause 3.5 equipped with a fire protected lobby. 1.2 This standard is not applicable to: - double-deck lifts; - lifts installed in existing buildings; - important modification to existing lift installed before the publication of this standard; - dual entry lifts, where the protected firefighters lift protected lobbies are not located on the same side as that of the fire service access level. However, this standard may usefully be used as a basis. 1.3 This standard deals with the significant hazards, hazardous situations and events relevant to firefighters lifts (as listed in clause 4) when they are used as intended and under the conditions as foreseen by the installer. 1.4 This document is applicable to new firefighters lifts in new buildings which are installed after the date of publication of this document by CEN. 1.5 This standard gives the additional or deviating requirements to EN 81-1 and 2 and prEN 81-5, 6 and 7 which shall be available for lifts which may be used for firefighting and evacuation purposes under firefighters control. In all other respects such lifts are designed in accordance with EN 81-1 and 2 and prEN 81-5, 6 and 7 where applicable. 1.6 This standard does not consider the use of lifts with partially enclosed wells for use as firefighters lifts. 1.7 This standard ceases to apply if the fire eventually breaks into a fire protected lobby (see annex A, Figure A.2). NOTE A firefighting concept is given in annex A.

Subjects

Lifts, escalators (91.140.90)


Buy this standard

Standard Swedish standard · SS-EN 81-72

Safety rules for the construction and installation of lifts - Particular applications for passenger and goods passenger lifts - Part 72: Firefighters lifts
Subscribe on standards - Read more Dölj
Price: 1 152 SEK
standard ikon pdf

PDF

Price: 1 152 SEK
standard ikon

Paper

Show more Show less

Product information

Language: English

Written by: SIS - Industriteknik

International title:

Article no: STD-34424

Edition: 1

Approved: 8/8/2003

No of pages: 31

Replaced by: SS-EN 81-72:2015 , SS-EN 81-72:2015